B. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-

ances to combustibles as specifi ed. Framing or fi nishing

material closer than the minimums listed must be construct-

ed entirely of noncombustible materials (i.e., steel studs,

concrete board, etc).
Clearance to combustible material under the insert is 1/4

inch (6 mm). Clearance from top of fi replace opening for

combustibles extending 12 inches max. is 12 inches.
• Use leveling legs to raise insert minimum 1/4 inch (6 mm)

above combustible material or outer wrap of factory built

fi rebox.

Combustible facings must not extend behind the insert

surround. For non-combustible material specifi cations

refer to section 1.E.

Figure 5.3 Mantel Clearances

12 IN. MIN.

12 IN. MAX.

EXISTING NON-COMBUSTIBLE FACING

C

D

SURROUND

APPLIANCE

1-1/2 IN.

B

D

A

D

APPLIANCE

SURROUND

MINIMUM FIREPLACE SIZE

Location

QFI35

QFI30

Inches

Millimeters

Inches

Millimeters

A

D

Alternate Unit Width

33-3/16

843

29-1/16

738

B

D

Alternate Unit Depth

15-1/16

383

13-7/8

352

C

D

Alternate Unit Height

22-9/16

573

19-1/16

484

* Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum

fi replace height for bends in vent pipe.

TOP VIEW

SIDE VIEW

Figure 5.2 Fireplace Opening - Deep Surround