Quadra-Fire • QFI30, QFI35 • 2227-900 Rev. H • 1/11

36

I. Air Shutter Setting

Air shutter settings should be adjusted by a qualifi ed ser-

vice technician at the time of installation. The air shutter is

set at the factory for minimum vertical vent run. Adjust air

shutter for longer vertical runs. See Figure 12.4.
NOTICE: If sooting occurs, provide more air by opening

the air shutter.

Figure 12.4 Air Shutter

Figure 12.3 Fixed Glass Assembly

H. Fixed Glass Assembly

Removing Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fi xed glass

assembly with care. Inspect the gasket to ensure it is

undamaged and inspect the glass for cracks, chips or

scratches.
DO NOT strike, slam or scratch glass.
DO NOT operate fi replace with glass removed, cracked,

broken or scratched.

Replace as a complete assembly.

Removing Fixed Glass Assembly

The glass assembly fastens to the fi replace in four

places. Four of the fastening mechanisms are spring-

loaded glass latches. An example of the glass latch

is shown in Figure 12.3.

• To release glass assembly, pull the two bottom

spring-loaded latches forward and allow them to re-

tract away from the glass assembly. Slide the glass

assembly outward and downward until the top latches
disengage.

Replacing Fixed Glass Assembly

Tilt glass assembly toward fi replace and slide glass

assembly upward to engage top latches. Verify top

latches are fully engaged and then fasten the two

bottom latches.

Air Shutter Settings

NG

LP

QFI30

5/16 in.

1/2 in.

QFI35

1/4 in.

1/2 in.