Packed valve handling precautions – Toshiba RAV-SM1100UT-E User Manual

Page 43

Advertising
background image

40

Gas side (15.9 mm (diam.))

Gas side (12.7 mm (diam.))

Gas side (9.5 mm (diam.))

Liquid side (6.4 mm (diam.))

Service port

20 to 25 N•m (6.3 to 7.7 kgf•m)

33 to 42 N•m (5.0 to 6.2 kgf•m)

33 to 42 N•m (3.3 to 4.2 kgf•m)

14 to 18 N•m (1.4 to 1.8 kgf•m)

14 to 18 N•m (1.4 to 1.8 kgf•m)

Compound
pressure gauge Pressure gauge

Manifold valve

Handle Hi
(Keep fully closed)

Charge hose

Vacuum pump
adapter for
counter-flow
prevention

Packed valve at gas side

Service port
(Valve core (Setting pin))

Handle Lo

Charge hose

–101kPa

(–76cmHg)

Vacuum
pump

Packed valve
at liquid side

Packed valve handling precautions

• Open the valve stem all the way out ; do not try to

open it beyond the stopper.

• Securely tighten the valve stem cap at the torque as

follows:

Hexagonal wrench is required.

• As shown in the figure, be sure to use a double

spanner to loosen or tighten the flare nut of the valve
at gas side. If using a single spanner, the nut cannot
be tightened with necessary tightening torque.

On the contrary, use a single spanner to loosen or
tighten the flare nut of the valve at liquid side.

Valve at gas side

Cover

Cap

Piping valve

Tightened

Flare nut

Loosened

Cover

Never put the spanner or
torque wrench, etc. on
the cover.

The valve may be broken.

Advertising