Others, 3) installation of ceiling panel, 4) cabling of ceiling panel – Toshiba RAV-SM1100UT-E User Manual

Page 69: Cautions

Advertising
background image

66

(3) Installation of ceiling panel

The angle change of the flap is possible while the power supply is turned

on. (Do not move forcibly the flap with hands. It may break the flap.)

1.

For tentative hanging, insert the tentative hanging metal (stainless) inside of

the ceiling panel into the square hole of the indoor unit. (Fig. 2)

The ceiling panel has directional ability against the indoor unit. Direct the

mark of

refrigerant pipe

at the ceiling panel corner toward the pipe side.

Holding the ceiling panel, remove it while pushing the tentative hanging

metal toward the outside.

Cor

ner of drain pipe

Square hole

of indoor unit

Ceiling panel

Draining mar

k

Scre

w

with w

asher

T

entativ

e hanging metal

Mar

k of

refr

igerant pipe

Square hole of indoor unit

T

entativ

e hanging metal

Push to remov

e

Indoor unit

No clearance

Ceiling panel

Ceiling surf

ace

2.

Match the mounting hole of the panel with the screw hole of the

indoor unit.

3.

Using the attached screws with washer, tighten 4 positions at

corners of the suction port until the panel is fitted closely to the

main unit. (Fig. 3)

4.

Check the panel is fitted closely to the ceiling.

In this time, check there is no clearance between the indoor unit

and the ceiling panel, and between the ceiling panel and the

ceiling surface. (Fig. 4)

(Fig. 2)

(Fig. 3)

(Fig. 4)

(4) Cabling of ceiling panel

1.

Open cover of the electric parts box.

2.

Connect the flap motor wiring connector out

of the ceiling panel to the connector 5P

(CN33: white) on P.C. board of the indoor unit.

Connect the connector surely because

the flap does not work if the connector

is not connected.

3.

Mount cover of the electric parts box in the

reverse procedure of opening of the cover.

Check whether the wiring connector is

pinched between the electric parts box

and the cover or not.

Check whether the wiring connector is

pinched between the indoor unit and the

ceiling panel or not.

As shown in the figure

, pass the clamping material through inside of the slit.

After connection, store the connector section in the electric par

ts bo

x.

Wiring explanation diag

ram

(F

or e

xplanation, direction of the indoor unit is changed.)

Electric par

ts bo

x cov

er

Scre

ws

(3 positions)

Flap motor

wiring connector

Clamper

CN33

• Tighten the screws securely because

a troub

le is caused as sho

wn in the

follo

wing figure if the scre

ws are

incompletely tightened.

• When there is a clearance between the

ceiling surf

ace and the ceiling panel

e

v

en if the scre

ws ha

v

e

been tightened,

readjust height of the indoor unit.

Air leak

Air leak

from ceiling

Generation

of dust

De

wing/w

ater

leak

Adjust so that there is

no clearance

.

Th

e he

ig

ht

o

f th

e in

do

or

u

n

it

ca

n be

a

d

ju

s

te

d

fr

om

co

rner ho

le

o

n

th

e ce

ilin

g pa

ne

l as

t

h

e

c

e

ili

n

g

p

a

n

e

l

is

i

n

s

ta

lle

d

i

f th

e ad

ju

st

me

nt

d

o

e

s

no

t af

fe

c

t th

e

le

v

e

ln

e

s

s

o

f th

e in

do

or

u

n

it

,

d

ra

in

pi

pe

, et

c.

Af

te

r ad

ju

st

me

nt

, be

s

u

re

to

t

ig

h

te

n

t

h

e

mo

un

ti

ng

n

u

t o

f

th

e

in

do

or

u

n

it

se

cu

re

ly

.

CAUTIONS

(Fig. 5)

(Fig. 6)

(Fig. 7)

(5) Installation of adjust corner cap/suction grille

Install the adjust corner cap/suction grille in the reverse procedure

of

installation to the indoor unit.

For this ceiling panel, as shown in the following figure, the

direction of the suction grille can be changed on customer

’s

demand when multiple indoor units are installed.

A. Installation of adjust corner cap

1.

Hook the strap of the adjust corner cap surely to the pin on the

ceiling panel.

2.

Install the adjust corner cap to the ceiling panel, and fix it with

the mounting screws. (accessory part)

B. Installation of suction grille

To install the suction grille, follow to the reverse procedure of the

removal. This ceiling panel can be installed from anyone of 4

directions by turning the suction grille. Change the direction on

the customer

’s demand or according to the direction matching of

the suction grille when multiple units are installed.

When installing the suction grille, be sure not to pinch the

flap motor wiring connector.

Be sure to attach a strap to prevent falling of the suction grille to

the ceiling panel.

3. Others

After confirmation of the above items, hand a set of this manual, manuals for the indoor unit,

manual for products sold separately, etc. to the customer. For cleaning of the filter, be sure to

ask the maintenance professional.

Pi

n

In

st

al

l th

e ad

ju

st

c

orne

r ca

p ho

riz

on

ta

lly

to

th

e ce

ilin

g su

rf

a

c

e

s

o

th

at

3

h

o

o

k

s

o

f

th

e ad

ju

st

c

orne

r ca

p ar

e se

t in

h

o

le

s

o

f

th

e ce

ilin

g pa

ne

l.

A

n

d

t

h

e

n

fi

x it

w

it

h

th

e

mo

un

ti

ng

s

c

re

ws

(

a

c

c

e

s

s

ory p

a

rt

).

A. Check after installation

Check again there is no clearance between the

indoor unit and the ceiling panel, and between

the ceiling panel and the ceiling surface.

*

A clearance causes water leak or dewing.

Check the cables are connected surely.

*

Incomplete connection causes a trouble such as the flap does not work.

B. For wireless remote controller

For details of installation, refer to the Installation Manual attached to the

wireless remote controller kit (sold separately).

P

o

s

it

io

n

s

o

f su

ct

io

n g

rill

e ho

ok

s at

s

h

ip

m

e

n

t fr

om

t

h

e

f

a

c

to

ry

*

Al

th

ou

gh

t

h

e

s

u

c

ti

o

n

g

rill

e

ca

n

be

i

n

s

ta

lle

d

f

ro

m

an

y

po

si

ti

on

o

f 4 co

rn

e

rs

, th

es

e po

si

ti

on

s ar

e re

co

mm

en

de

d.

It

i

s

un

ne

ce

ss

ary

to

re

mo

v

e

th

e su

ct

io

n g

rill

e in

ma

in

te

na

nc

e

fo

r t

h

e

e

le

c

tric

pa

rt

s

b

o

x

of

t

h

e

i

n

d

o

o

r

un

it

.

( )

Re

frig

er

an

t pi

pe

si

de

o

f

in

do

or

u

n

it

Dr

ai

n pi

pe

s

id

e

o

f in

do

or

u

n

it

El

ec

tric

p

a

rt

s

b

o

x

o

f in

do

or

u

n

it

Wi

re

le

ss

r

e

m

o

te

co

nt

ro

ller

k

it

(s

ol

d se

pa

ra

te

ly

)

Di

re

ct

io

n-

fr

ee

i

n

36

0

˚

EH99708701-(1)

(EN)

(Fig. 8)

(Fig. 9)

Hook hole of

ceiling panel

Hook of

fall-pre

v

entiv

e strap

Advertising
This manual is related to the following products: