Installation Place

• A place which provides a specified space around the

outdoor unit.

• A place where the operation noise and discharged air

are not given to your neighbors.

• A place that is not exposed to a strong wind.

• A place that does not block a passage.

• When the outdoor unit is installed in an elevated

position, be sure to secure its feet.

• There must be sufficient space for carrying in the

unit.

• A place where the drain water does not make any

problem.

CAUTION

1. Install the outdoor unit at a place where dis-

charge air is not blocked.

2. When an outdoor unit is installed in a place that

is always exposed to a strong wind like a coast
or on a high storey of a building, secure a
normal fan operation by using a duct or a wind
shield.

3. When installing the outdoor unit in a place that is

constantly exposed to a strong wind such as the
upper stairs or rooftop of a building, apply the
windproof measures referring to the following
examples.

1) Install the unit so that its

discharge port faces to the
wall of the building. Keep a
distance 500 mm or more
between the unit and the
wall surface.

500

Strong
wind

Strong
wind

2) Supposing the wind direction during the

operation season of the air conditioner, install
the unit so that the discharge port is set at
right angle to the wind direction.

4. Installation in the following places may result in

some troubles. Do not install the unit in such
places below.

• A place full of machine oil.

• A place full of sulphuric gas.

• A place where high-frequency radio waves are

likely to be generated as from audio quipment,
welders, and medical equipment.

150

or more

300

or more

300

or more

300

or more

200 or more

The height of the obstacle should be lower

than the height of the outdoor unit.

1000

or more

Necessary Space for Installation

Obstacle at rear side

<Upper side is free>

1. Single unit installation

150

or more

150

or more

300

or more

200

or more

The height of the
obstacle should be
lower than the height
of the outdoor unit.

500

or more

150

or more

500

or more

2. Obstacles at both right and left sides.

3. Serial installation of two or more units

<Obstacle also at the upper side>

Obstacle at front side

<Upper side is free>

1. Single unitIn installation

2. Serial installation of two or more units