Toshiba RAV-SM1100UT-E User Manual

Page 55

Advertising
background image

52

HO

W T

O

OPERA

TE THE

UNIT

Cool/Heat A

U

T

O

, Heat,

Dry

, Cool,

F

a

n

P

o

wer suppl

y

T

u

rn

on the po

w

er of the wireless remote controller 12 hours bef

ore star

ting the oper

ation.

After the po

wer supply has been tur

ned on, the oper

ation of the remote controller is not

accepted f

or appro

x.

1 minute

. It is not a f

ailure

.

(The sensor receiv

es the signal once

, b

ut the receiv

ed contents are cleared.)

4

Push either

or

to select the desired temperature

.

Dur

ing F

AN mode

, the temper

ature cannot be set up

.

5

Stop

Push Star

t/Stop b

utton.

When using the remote controller to stop the unit, the outdoor unit f

an ma

y k

eep oper

ating f

o

r

a while e

v

en if the compressor of the outdoor unit has stopped.

In heating

operation,

if

the

room

is

not

comf

o

r

ta

b

ly

heated

with

F

A

N

, select

F

A

N

or

.

Although the

y are displa

y

ed, the function ma

y not be pro

vided according to the used indoor

unit.

(F

an speed is constant.)

When the unit

cannot

be

stopped

b

y

the normal

operation

T

u

rn

off the po

wer s

witch

or leakage

break

e

r, and then contact the shop which y

ou purchased

the unit.

A

utomatic cool/heat

When all indoor units in the identical refr

iger

ant system are controlled as a group

, the cooling/

heating oper

ation is automatically perf

o

rmed with the diff

erence betw

een the setup temper

ature

and the room temper

ature.

Dry operation

There is no dr

y function according to the used indoor unit e

v

en if DR

Y is displa

y

ed on the

displa

y section of the remote controller

. (Same to Cooling oper

ation)

When the room temper

ature approaches the setup temperature

, r

unning/stop oper

ations are

automatically repeated.

In order not to retur

n humidity to the room as possib

le, the mode of indoor f

an enters LO

W

mode when the oper

ation has stopped.

The f

an speed cannot be adjusted according to the used indoor unit or status of the room

temperature.

The DR

Y mode cannot be used according to the used indoor unit when the outdoor temper

a

-

ture is 15

˚C or

lo

we

r.

1

Push Star

t/Stop

b

utton.

2

Push

(Operation Select b

utton)

operation to select one of

,

,

,

, and

.

3

Push

(F

an Mode Select b

utton)

to select one of fan speed modes.

When selecting

, the f

an speed is

automatically changed.

(Dur

ing F

AN mode

, the air speed is

not automatically changed.)

3

4

2

1

HO

W T

O

OPERA

TE THE TIMER

After setting of the timer

, set the remote controller at a position where the signal can reach the

sensors (indoor unit body) .

(The signal of the timer oper

ation is sent from the remote controller

.)

Set up the timer dur

ing displa

y of the oper

ation mode

.

Use in the f

ollo

wing cases

T

o

stop the air conditioner

after the pre

viously set time

has passed

T

o

stop the air conditioner

e

v

er

y time after the pre

viously

set time has passed

T

o

operate the air conditioner

after the pre

viously set time

has passed

During displa

y

Timer time

Ev

er

y pushing

, the setup time increases b

y

0.5 hour (30 min

utes).

The maxim

um time to be set is 72.0 hours

.

Ev

er

y pushing

, the setup time decreases b

y

0.5 hour (30 min

utes).

The minim

um time to be set is 0.5 hours

.

Timer displa

y

Ev

er

y pushing

SET

, the displa

y changes as

follo

ws;

<Use e

xample>

H

o

w to use OFF timer

(Ex.)

T

o

stop the unit 30 min

utes after

1

W

hen pushing the timer

SET

once

,

and the time flash on the remote

contr

oller

.

2

Push TIME

or

to set the time

to 0.5.

3

Push

SET

and the

go on timer

.

H

o

w to use the repeat timer

(Ex.)

T

o

stop the air conditioner e

v

e

ry time

after 2.5 hours has passed

1

When pushing the timer

SET

twice,

,

and the time flash on the

remote contr

oller.

2

P

ush TIME

or

to set the time

to 2.5.

3

Push

SET

and the

,

go

on

timer

.

The

wo

rk

s

,

and the operation stops

after 2.5 hours

. When pushing

(Star

t/Stop)

b

utton again to oper

ate the

unit, the operation stops after 2.5 hours

.

H

o

w to use ON timer

(Ex.)

T

o

oper

ate the unit 8 hours after

1

When pushing the timer

SET

three

times,

and the timer flash on the

remote contr

oller

.

2

Push TIME

or

to set the time

to 8.0.

3

Push

SET

The operation mode displa

y disappears

,

and then time and the

go on.

T

o

stop the timer operation

T

o

stop the timer operation

Push

C L

b

utton.

Then the timer displa

y

disappears

.

ADR

No display

Advertising
This manual is related to the following products: