Operation Section

Push each b

utton to select a desired oper

ation.

The details of the oper

ation needs to be set up once

, afterw

ard, the air conditioner can be

used b

y

pushing

b

utton only

.

1

Operation select b

utton

Selects desired oper

ation mode

.

2

F

an mode select b

utton

Selects a f

an mode

.

3

Timer set b

utton

TIMER SET b

utton is used when the

timer is set up

.

4

Chec

k b

utton

CHECK b

utton

is

used

for

chec

k

oper

ation.

Dur

ing nor

mal oper

ation, do

not use this b

utton.

5

T

emperature set b

utton

Adjusts required room temper

ature

.

Set required set temperature b

y

pushing

or

.

6

S

tar

t/Stop b

utton

When the b

utton is pushed, operation star

ts

,

and it stops b

y

pushing the b

utton again.

When the operation stops

, the oper

ation lamp

and all displa

ys disappear

.

7

Filter reset b

utton

Resets (Erases)

“FIL

TER

” displa

y.

OPTION :

Remote contr

oller sensor

Usually the

TEMP

. sensor of the indoor unit

measured a temper

ature

. A temperature around

the remote controller can also be measured.

F

or details

, contact the dealer from which y

o

u

ha

v

e

purchased the air conditioner

.

SET

ACL

SE

NS

OR

CL

ADR

7

2

1

4

3

5

6

Displa

y Section

All indicators are sho

wn in the r

ight and the lo

wer figures f

or the

e

xplanation.

Only selected contents are displa

y in actual oper

ation.

When tur

ning on the leakage break

er at the first time 3

min

utes later

,

[SET D

A

T

A

] flashes about f

or 1 min

ute on the

displa

y par

t of the remote controller

.

While this displa

y is

flashing, the model is being automatically confir

med.

Accordingly

, w

ait f

or 1 min

ute after

[SET D

A

T

A

] displa

y has

disappeared, and then use the remote controller

.

ADR

ACL

SENS

OR

SET

CL

ADR

Displa

y

section

Operation

section

1

T

ransmitting indication

Displa

y

ed while operating the s

witches of

the remote controller

.

2

Mode displa

y

The selected oper

ation mode is displa

y

ed.

3

F

an mode select displa

y

The selected

fan mode is displa

y

ed.

(A

U

T

O

)

(HIGH)

(MED

.)

(LO

W)

4

Filter displa

y

If

“FIL

TER

” is displa

y

ed, clean the air

filter

.

5

CHECK displa

y

Displa

y

ed while the protectiv

e de

vice

w

o

rks or a troub

le occurs

.

6

Set up temperature displa

y

The selected set up temp

. is displa

y

ed.

7

Flap position displa

y

8

SWING displa

y

Displa

y

ed dur

ing up/do

wn mo

v

ement of

the flap

.

9

Timer time displa

y

Time of the timer is displa

y

ed.

(When a troub

le occurs

, the chec

k code is

displa

y

ed.)

10

Timer SETIN setup displa

y

When pushing the

Timer SET b

utton,

the displa

y of the timer is selected in

order of [OFF]

®

[OFF] repeat OFF timer

®

[ON]

®

No displa

y.

ADR

1

10

2

3

4

5

6

8

7

9