Parameter measurement information, Signal transition levels – Texas Instruments TMS320C6712D User Manual

Page 63

Advertising
background image

TMS320C6712D

FLOATINGĆPOINT DIGITAL SIGNAL PROCESSOR

SPRS293A − OCTOBER 2005 − REVISED NOVEMBER 2005

63

POST OFFICE BOX 1443

HOUSTON, TEXAS 77251−1443

PARAMETER MEASUREMENT INFORMATION

Transmission Line

4.0 pF

1.85 pF

Z0 = 50

(see note)

Tester Pin Electronics

Data Sheet Timing Reference Point

Output
Under
Test

NOTE: The data sheet provides timing at the device pin. For output timing analysis, the tester pin electronics and its transmission line effects

must be taken into account. A transmission line with a delay of 2 ns or longer can be used to produce the desired transmission line effect.
The transmission line is intended as a load only. It is not necessary to add or subtract the transmission line delay (2 ns or longer) from
the data sheet timings.

42

3.5 nH

Device Pin
(see note)

Input requirements in this data sheet are tested with an input slew rate of < 4 Volts per nanosecond (4 V/ns) at the device pin.

Figure 15. Test Load Circuit for AC Timing Measurements

signal transition levels

All input and output timing parameters are referenced to 1.5 V for both “0” and “1” logic levels.

Vref = 1.5 V

Figure 16. Input and Output Voltage Reference Levels for ac Timing Measurements

All rise and fall transition timing parameters are referenced to V

IL

MAX and V

IH

MIN for input clocks, and

V

OL

MAX and V

OH

MIN for output clocks.

Vref = VIL MAX (or VOL MAX)

Vref = VIH MIN (or VOH MIN)

Figure 17. Rise and Fall Transition Time Voltage Reference Levels