Asynchronous memory timing, See figure 26−figure 27) – Texas Instruments TMS320C6712D User Manual

Page 70

Advertising
background image

TMS320C6712D

FLOATINGĆPOINT DIGITAL SIGNAL PROCESSOR

SPRS293A − OCTOBER 2005 − REVISED NOVEMBER 2005

70

POST OFFICE BOX 1443

HOUSTON, TEXAS 77251−1443

ASYNCHRONOUS MEMORY TIMING

timing requirements for asynchronous memory cycles

†‡

(see Figure 26−Figure 27)

NO.

−150

UNIT

NO.

MIN

MAX

UNIT

3

tsu(EDV-AREH)

Setup time, EDx valid before ARE high

6.5

ns

4

th(AREH-EDV)

Hold time, EDx valid after ARE high

1

ns

6

tsu(ARDY-EKOH)

Setup time, ARDY valid before ECLKOUT high

3

ns

7

th(EKOH-ARDY)

Hold time, ARDY valid after ECLKOUT high

2.3

ns

† To ensure data setup time, simply program the strobe width wide enough. ARDY is internally synchronized. The ARDY signal is recognized in

the cycle for which the setup and hold time is met. To use ARDY as an asynchronous input, the pulse width of the ARDY signal should be wide
enough (e.g., pulse width = 2E) to ensure setup and hold time is met.

‡ RS = Read setup, RST = Read strobe, RH = Read hold, WS = Write setup, WST = Write strobe, WH = Write hold. These parameters are

programmed via the EMIF CE space control registers.

switching characteristics over recommended operating conditions for asynchronous memory
cycles

द

(see Figure 26−Figure 27)

NO.

PARAMETER

−150

UNIT

NO.

PARAMETER

MIN

MAX

UNIT

1

tosu(SELV-AREL)

Output setup time, select signals valid to ARE low

RS*E − 1.7

ns

2

toh(AREH-SELIV)

Output hold time, ARE high to select signals
invalid

RH*E − 1.7

ns

5

td(EKOH-AREV)

Delay time, ECLKOUT high to ARE valid

1.5

7

ns

8

tosu(SELV-AWEL)

Output setup time, select signals valid to AWE low

WS*E − 1.7

ns

9

toh(AWEH-SELIV)

Output hold time, AWE high to select signals and EDx invalid

WH*E − 1.7

ns

10

td(EKOH-AWEV)

Delay time, ECLKOUT high to AWE valid

1.5

7

ns

11

tosu(EDV-AWEL)

Output setup time, ED valid to AWE low

(WS−1)*E −

1.7

ns

‡ RS = Read setup, RST = Read strobe, RH = Read hold, WS = Write setup, WST = Write strobe, WH = Write hold. These parameters are

programmed via the EMIF CE space control registers.

§ E = ECLKOUT period in ns
¶ Select signals include: CE[3:0], BE[1:0], EA[21:2], and AOE.