Maintenance – Universal Laser Systems CLP-100NI-NPRT User Manual

Page 33

Advertising
background image

33

7- Retighten the Brass Tipped Set Screw to lock the Index Ring in position. This screw must be tight to

prevent the Index Ring from rotating under spring tension.

6- Rotate the Index Ring in a clockwise direction until it stops turning. Next, turn the Index Ring in the

counterclockwise direction as necessary until the Brass Tip Set Screw is pointing directly at the
Transfer Roll Axle as shown in Figure 63.

5- Using a 1/8" hex wrench, loosen the Brass Tipped Set Screw

located in the side of the Index Ring until the Index Ring
rotates freely.

MAINTENANCE

Important Note: The Print Drum Axle is machined with thread
relief as shown in Figure 40 so the tip of the set screw will not
damage the threads. To completely remove the Index Ring from
the Axle, the Brass Tip Set Screw must be loosened at least 2
full turns to prevent damage to the threads.

FIGURE 63

FIGURE 62

.04

BRASS TIP
SET SCREW

PRINT DRUM AXLE

RECESS AREA

LEFT HAND

CONFIGURATION

RIGHT HAND

CONFIGURATION

INDEX RING

BRASS TIP SET SCREW

TRANSFER

ROLL AXLE

INDEX PLUNGER

INDEX RING PIN

FIGURE 61

Advertising