5800 series transmitters table, Installing 5800 series transmitters – Vista Ademco N7227V5 User Manual

Page 24

Advertising
background image

VISTA-10SE Installation and Setup Guide

5-6

5800 Series Transmitters Table (

continued)

Model

Description

Input Type and Special Notes

5817
(cont'd.)

Multi-Point Universal
Transmitter
(cont'd.)

DIP Switches:

Set all DIP switches to the OFF position when enrolling the
serial number.

NOTE: All loops must be assigned the same input type.

5818

Recessed Magnetic
Contact Transmitter

Enroll as “3” for RF (supervised).

5819

5819

BRS

5819

WHS

Shock Processor
Transmitter

Enroll as “3” for RF (supervised).
Has three unique input (loop) zones: one for a wired closed-circuit contact loop,
one for use with inertia-type shock detectors (mounted externally), and one for a
built-in reed switch (used in conjunction with a magnet).

5849
5850
5852

Glassbreak
Detector/Transmitter

Enroll as “3” for RF (supervised).

5890
5890P1

PIR Detector/
Transmitter

Enroll as “3” for RF (supervised).
The cover must be on the unit when enrolling the serial number.

When “enrolling” a transmitter’s ID code(s), any PIR in the vicinity that is not being enrolled
should be covered with a cloth, tissue, etc. to prevent activation.

Installing 5800 Series Transmitters

To be sure reception of the transmitter's signal at the proposed mounting location is
adequate, perform a Go/No Go Test in the TESTING the SYSTEM section.

Setting DIP Switches on the 5827 Transmitter(s)

You must set a 5827 Transmitter to the programmed House ID, using its DIP switches.

DIP SWITCH POSITION

1

2

3

4

5

1

-

-

-

-

UP

2

-

-

-

UP

-

3

-

-

-

UP

UP

4

-

-

UP

-

-

5

-

-

UP

-

UP

6

-

-

UP

UP

-

7

-

-

UP

UP

UP

8

-

UP

-

-

-

9

-

UP

-

-

UP

10

-

UP

-

UP

-

11

-

UP

-

UP

UP

12

-

UP

UP

-

-

13

-

UP

UP

-

UP

14

-

UP

UP

UP

-

15

-

UP

UP

UP

UP

16

UP

-

-

-

-

DIP SWITCH POSITION

HOUSE

ID

1

2

3

4

5

17

UP

-

-

-

UP

18

UP

-

-

UP

-

19

UP

-

-

UP

UP

20

UP

-

UP

-

-

21

UP

-

UP

-

UP

22

UP

-

UP

UP

-

23

UP

-

UP

UP

UP

24

UP

UP

-

-

-

25

UP

UP

-

-

UP

26

UP

UP

-

UP

-

27

UP

UP

-

UP

UP

28

UP

UP

UP

-

-

29

UP

UP

UP

-

UP

30

UP

UP

UP

UP

-

31

UP

UP

UP

UP

UP

SWITCH UP FOR "ON"

SWITCH DOWN FOR "OFF"

SHOWN SET FOR
HOUSE ID # 30

Advertising
This manual is related to the following products: