VISTA-10SE Installation and Setup Guide

13-2

Type 05

Trouble by Day/

Alarm by Night

Zone type 05 is usually assigned to a zone that contains foil-protected doors
or windows; or covers a sensitive area (e.g., stock room, drug supply room,
etc.) It can also be used on a sensor or contact in an area where immediate
notification of an entry is desired.

Zone Characteristics

:

Provides an instant alarm when armed in AWAY, STAY, INSTANT, or

MAXIMUM (night) mode.

Provides a latched trouble sounding from the keypad and, if desired, a

central station report during the disarmed state (day).

Type 06

24-hour Silent Alarm

Zone type 06 is usually assigned to a zone containing an Emergency button.

Zone Characteristics:

Sends a report to the central station but provides no keypad display or

sounding.

Type 07

24-hour Audible Alarm

Zone type 07 is usually assigned to a zone containing an Emergency button.

Zone Characteristics:

Sends a report to the central station, and provides alarm sounds

externally and at the keypad.

Type 08

24-hour

Auxiliary Alarm

Zone type 08 is usually assigned to a zone containing a button for use in
personal emergencies or to a zone containing monitoring devices (e.g., water
or temperature sensors, etc.).

Zone Characteristics:

Sends a report to the central station and provides an alarm sound at the

keypad. (No bell output is provided and there is no keypad timeout.)

Type 09

Supervised Fire

5806/5807/5808

01000-020-V0

Zone type 09 can be assigned to any wireless zone used as a fire zone. This
zone type is always active and cannot be bypassed.

Zone Characteristics:

Bell output will pulse when this zone type is alarmed.

Type 10

Interior w/Delay

Zone type 10 is bypassed when the panel is armed in the STAY or INSTANT
mode.

Zone Characteristics:

Entry delay #1 (with programmed entry time) when armed in the AWAY

mode.

Entry delay begins whenever sensors in this zone are violated,

regardless of whether an entry/exit delay zone was tripped first.

No entry delay when armed in the MAXIMUM mode.

Exit delay regardless of the arming mode selected.