S E C T I O N 7

4285 and 4286 VIP Module

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

In This Section

Installing the VIP Module

Programming the 4285/4286 VIP Module

Checking 4285/4286 VIP Module Operation

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

Installing the (Voice Interactive Phone) Module

General Information

The 4285/4286 VIP Module is an add-on accessory for the VISTA–10SE that permits access to
the security system via a TouchTone phone (either on premises or by a call-in when away).

The VIP Module can announce many of the same words that would normally be displayed on
an alpha keypad under the same system conditions.

When using the VIP Module, addressable keypads must be used in the system, but set to the
non-addressable mode (address 31); i.e., do not use a 6127 keypad.

When properly connected, the VIP Module will enable the user to do the following via a
TouchTone telephone:

Receive synthesized voice messages over the phone regarding the status of the security

system.

Arm and disarm the security system and perform most other commands using the

telephone keypad, with voice annunciation provided over the phone as confirmation after
a command is entered.

The phone used for phone access must have TouchTone capability, though TouchTone service
is not necessary (if premises uses PULSE dialing, switchable phones must be set for
TouchTone temporarily before attempting phone access).

A Phone Access User's Guide for phone access to the security system is provided with the
VIP Module for the user of the system.

UL

The VIP Module is not Listed for UL installation use

.

Mounting the VIP Module

The VIP Module may be mounted in the control cabinet if space is available or, if this is not
possible, on the side of the cabinet or adjacent to it.

When mounting the VIP Module outside the cabinet, use the screw holes at its rear. That will
permit it to be mounted horizontally or vertically (double-sided tape may be used, if
preferred). Wires can be brought out from the side or back (a round breakout is also available
on the back).

Affix the VIP Module’s connections label (supplied separately) to the inside of the VIP
Module's cover if the cover is used. If you have installed the module within the cabinet, affix
the label to the inside of the control cabinet's door.