VISTA-10SE Installation and Setup Guide

11-2

AC Power-Up

To turn on AC power, perform the following steps:

1.

Plug the 1321/1321CN into a 24-hour, unswitched 120VAC outlet.

Following power-up, one of the following is displayed on the keypad: AC, dI (disabled);
BUSY STANDBY (on alpha keypads); or NOT READY (on fixed-word keypads). The
green POWER LED (or READY LED on some keypads) should light.

2.

After approximately 1 minute, the initial displays revert to DISARMED...READY TO
ARM
for alpha keypads, or READY for fixed-word keypads (if there are no faulted
zones). This 1-minute delay allows PIRs, etc. to stabilize.

To bypass this delay, press: # + 0.

NOTE: If you do not get the “READY” displays described above, refer to “Trouble

Conditions” in the SYSTEM OPERATION section.

Calculating the Battery Size Needed

Determine the total device current draw after filling in the AUXILIARY DEVICE CURRENT
DRAW WORKSHEET that follows. To this figure add the 100mA that is drawn by the control
panel itself. Then, to determine the battery size needed, use the following formula:

Total Current Drawn* x Number of hours standby wanted = Battery Ampere/Hours.

* Convert mA figure to decimal Amps (see example that follows).

Example: If total auxiliary device current drain is 450mA, add 100mA for the control panel,
for a total of 550mA (0.55 amps); if 24-hour standby is wanted, the calculation is:

0.55A x 24 hours = 13.2 Ampere/Hour battery needed

In this example, two 7 Amp/Hr batteries (connected in parallel) must be used.

AUXILIARY DEVICE CURRENT DRAW WORKSHEET

DEVICE

CURRENT

# UNITS

TOTAL CURRENT

6128 Keypad

30mA

6139 Keypad

100mA

5881/5882 RF Receiver

35mA

4204 Relay Unit

15/180mA‡

4285 VIP Module

160mA

4286 VIP Module

300mA

*

*

*

TOTAL =

Current available from Aux. terminals = 600mA max (500mA max for UL installations)**

*

If you are using hardwire devices such as PIRs, refer to the specifications for that particular unit's
current draw.

**

In UL installations, maximum current draw from the Auxiliary Output and the Alarm Output
combined must not exceed 600mA.

Figures are for relays de-energized (OFF)/relays energized (ON).