Section 13 – Zone Response Type Definitions

13-3

Type 20

Arm–STAY

Zone type 20 is a special-purpose zone type used with 5800 Series wireless
pushbutton transmitters.

Zone Characteristics:

Exit delay regardless of the arming mode selected.

System is armed in the STAY mode when the zone is activated.

Zone number is sent to the central station as a user number when

arming or disarming.

Type 21

Arm–AWAY

Zone type 21 is a special-purpose zone type used with 5800 Series wireless
pushbutton units.

Zone Characteristics:

System is armed in the AWAY mode when the zone is activated.

Zone number is sent to the central station as a user number when

arming or disarming.

Type 22

Disarm

Zone type 22 is a special-purpose zone type used with 5800 Series wireless
pushbutton.

Zone Characteristics:

Disarms the system when the zone is activated.

Type 23

No Alarm Response

Zone type 23 can be used when the action of a relay is desired, but with no
accompanying alarm (e.g., a front or back door light being turned on or off).