VISTA-10SE Installation and Setup Guide

12-2

If a different Installer code is subsequently programmed, use it instead of 4111 to gain
access to the Programming mode.

When you enter the Program mode, data field

20 is displayed (this is the first data field in

the system). The system now accepts entries for field

20.

Programming a Data Field

1. Press [

]+ Field No. (for example,

21), then make the desired entry.

2. When you have completely programmed a data field, the keypad beeps three times and

then automatically displays the next data field in sequence. To go to a different field,
press [

]

plus the desired field number.

3. If the number of digits that you need to enter in a data field is less than the maximum

digits available (for example, the phone number field), enter the desired data, then press
[

] and the next data field number to be programmed.

4. If you try to enter a nonexistent field, the keypad will display NOT USED EE (Entry

Error). Simply re-enter [

] plus a valid field number.

Reviewing a Data Field/Erasing an Entry

Press [#] + Field No. Data is displayed for that field number. No changes are accepted in
this mode.

To delete an entry in a field, press [

] + Field No. + [

] (applies only to fields

40-

43, and

94).

Interactive Mode Programming (

56,

58,

80,

81, and

82)

Typical prompt displayed
during Interactive mode
programming:

Enter Zn Num.

(00 = Quit)

01

Zone Number

Ç

Press [

] + Interactive Mode No. (for example,

56). The

alpha keypad displays the first of a series of prompts requesting
entries.

A detailed procedure (with displays of prompts) is provided in
later sections of this manual.

Interactive Mode

Used to Program

✱56 Zone Programming

Zone characteristics, report codes, alpha
descriptors, and serial numbers

✱58 Expert Mode

Programming

Zone characteristics, report codes, and
serial numbers.

✱80 Output Relay

Programming

4204 Relay module

✱81 Zone List

Programming

Zone lists for relay control

✱82 Alpha Programming

Zone alpha descriptors

Loading Factory Defaults

To load the factory defaults, enter the Programming mode, press

97, then exit the

Programming mode.

Do not press

97 to load defaults if any programming has been done previously. If you do, data

already programmed into the system will be changed!

96 resets all the subscriber account numbers and CSID in preparation for an initial

download.

Exiting the Programming Mode

99 allows re-entry into the Program mode using Installer Code + 8 0.

98 prevents re-entry into the Programming mode using the Installer code.