Xantrex Technology GT3.0 User Manual

Page 48

Advertising
background image

Installation

2–20

975-0131-01-01

Mounting on Poles or Rails

To mount the unit using poles:

1.

Ensure that poles or rails are securely assembled in place. If using horizontal
rails, three rails are required: two for the mounting bracket and a third for
securing the bottom edge of the inverter wiring box (see Figure 2-9).

2.

Connect the mounting bracket vertically to the poles or rails (Figure 2-9):

Be sure to use at least two bolts to secure the mounting bracket to the
support.

Position the lower edge of the bracket a minimum of 110 cm (43 inches)
above the floor or ground.

3.

If using a single vertical pole, ensure that the inverter is secure and unable to
rotate around the pole.

Figure 2-9 Examples of Mounting on a Pole or Rails

Ground /

Floor

Ground /

Floor

Mounting Bracket

110 cm

(43”)

100 cm

(39”)

At least 2 bolts to
secure bracket to

poles/rails.

15 cm

(5.9”)

48 cm

(18.9”)

For securing

the bottom of

the wiring box

Advertising