Electrical Specifications

975-0131-01-01

A–3

Adjustable Disconnect Settings

The adjustable disconnect setting values vary depending on whether the inverter is
a 208 Vac/60 Hz, 240 Vac/60 Hz, or 230 Vac/50 Hz model. Utility permission is
required prior to changing the settings on the inverter.

The default values of these settings differ from the utility specifications on
page A–2. These differences take into account the accuracy ranges listed in the
table below, and are intended to ensure that utility specifications are always met.

Output Power Versus Ambient Temperature

Once the heat sink on the inverter reaches a maximum temperature limit, the GT
Inverter reduces its energy output to ensure maximum component ratings are not
exceeded.

Setting

Default Values

Adjustment Range

Accuracy

208 Vac/60 Hz 240 Vac/60 Hz 230 Vac/50 Hz

From...

To...

AC Low Voltage

186 Vac

214 Vac

205 Vac

180 Vac

269 Vac

+/– 3 Vac

AC High Voltage

225 Vac

261 Vac

250 Vac

AC Low Frequency

59.4 Hz

47.1 Hz

46.0 Hz

62.0 Hz

+/– 0.1 Hz

AC High Frequency

60.4 Hz

50.9 Hz

Reconnect Delay

305 sec.

60 sec.

600 sec.

+/– 5 sec.

Figure A-1 Output Power vs. Ambient Temperature

GT3.0 GRID TIE SOLAR INVERTER

Output Power versus Ambient Temperature

0

500

1000

1500

2000

2500

3000

3500

-25

-15

-5

5

15

25

35

45

55

65

Ambient Temperature (C)

P

o

w

e

r (W

a

tts

)

Standard Unit

w/ Optional Fan Kit