Replacing Parts

975-0131-01-01

6–7

To replace the inverter on the wiring box:

1.

If it has not already been removed, remove the front panel cover on the
inverter now. The wiring box cover should have been removed in the previous
procedure.

2.

Mount the inverter on the upper mounting bracket above the wiring box, with
the lower flange behind the wiring box.

3.

Replace the nuts that connect the inverter and the wiring box. Secure all nuts
tightly.

4.

Remove the wire nut from the PV NEGATIVE (–) wire and reconnect it to the
terminal block inside the inverter.

5.

Uncap the remaining DC and AC wires and reconnect them to the terminal
block inside the inverter.

6.

Replace the front panel and wiring box covers (described on page 2–23 and
page 4–3).

7.

Turn ON the breaker switches in the main utility service panel and the AC/DC
Disconnect switch on the GT Inverter.

Figure 6-2 Inverter and Wiring Box Sections

Inverter

Wiring box

Lower flange
behind wiring box

Front view

Back view