Electrical specifications, Input output – Xantrex Technology GT3.0 User Manual

Page 96

Advertising
background image

Specifications

A–2

975-0131-01-01

Electrical Specifications

Input

Output

Input voltage, Maximum Power Point range

195 to 550 Vdc

Absolute maximum array open circuit voltage

600 Vdc

Maximum input current

16.6 A DC

Maximum array short circuit current

19 A DC

Recommended PV array power

Up to 3300 W

Reverse polarity protection

Short circuit diode

Ground fault protection

GF detection, I

DIF

> 1 A

GT3.0 North American

GT3.0 European

Maximum output power

3000 W AC

3000 W AC

Nominal output power over rated temp range

2500 W AC

2500 W AC

Maximum utility backfeed current

20 A

20 A

Nominal output voltage

240 V

230 V

Operating range, utility voltage (default)*

*

Requires Utility permission and qualified service personnel to change settings.

211 to 264 Vac

202 to 253 Vac

Nominal output frequency

60 Hz

50 Hz

Operating range, utility frequency (default)*

59.3 to 60.5 Hz

47.1 to 50.9 Hz

Maximum continuous output current

14.2 A

14.9 A

Output overcurrent protection

20 A RMS

20 A RMS

Total Harmonic Distortion (THD)

<5%

<5%

Power factor

>0.9

>0.9

Utility monitoring—islanding protection

Vac, fac as per UL1741

Output characteristics

Current source

Output current waveform

Sine wave