Tools, Installation considerations, Safety – Xantrex Technology Link 1000 User Manual

Page 17: Performance, Safety performance

Advertising
background image

Planning the Installation

9

❐ 2 strain reliefs (cable clamps) for the wires and phone

cable coming out the back of the control panel

❐ Anti-corrosive spray

❐ High current shunt. If your starter current exceeds 500

amps for more than ten seconds, you will need a heavy
duty (1000 amp) shunt instead of the 500 amp shunt that
is supplied with the Link 1000. (You can also use a
separate engine starting battery whose negative is
connected directly to the engine.) The heavy duty shunt
part number is 84-2-13-00.

Tools

❐ Wire cutter and stripper

❐ Small slot head screwdriver (for the screws on the

terminal block)

❐ Phillips screwdriver (for the control panel mounting

screws)

❐ Needle-nose pliers

❐ 9/16 in. wrench to secure cables to the shunt

Installation Considerations

Safety

•

If you are using flooded lead-acid batteries, install them
in a separate battery compartment.

•

Wiring should be in accordance with NEC, ABYC, or
other applicable national or regional codes.

Performance

•

Do not connect anything other than the shunt to the
negative battery terminal. Connect all other loads and
sources to the load side of the shunt. (See

Figure 2

.)