F14 test control panel display, F15 display software revision number, F16 turn on active temperature compensation – Xantrex Technology Link 1000 User Manual

Page 42

Advertising
background image

About Link 1000 Settings

34

F14 Test Control Panel Display

Default:

Off

Range:

On while the

SET

button is pressed when this

function is active. Off when

SET

is released.

This function lets you confirm that the Link 1000 control
panel display is operating properly. When you press

SET

in

F14 mode:

The

RESET

and

DATA

LEDs are orange-yellow.

All other LEDs display their normal color.

The Numeric Display reads

188.8.

The display returns to normal when you release

SET

.

Operation of the

LOCK

and

FUNC

LEDs is confirmed when

power is initially applied to the Link 1000.

F15 Display Software Revision Number

Press

SET

to display the Software Revision Number.

This function displays the software revision number installed
in your Link 1000. Record this number on

page 60

in case

you need to call Customer Service.

F16 Turn on Active Temperature Compensation

Default:

Off

Range:

Off, On

Turn this function On if your inverter/charger has a
temperature sensor.

Leave this function Off if you are not using a temperature
sensor.

When this function is On, the Link 1000 uses the actual
battery temperature reported to the Freedom Inverter/Charger
by a Heart TC2+2 unit, the Freedom 458 or the Freedom
Marine Inverter/Charger temperature sensor.