Charging Functions

41

Check the electrolyte level of all batteries before and
after equalization. Make sure the electrolyte is at the
correct level, but do not overfill because the electrolyte
may expand and overflow.

Leave the filler caps screwed on loosely, or remove them
and cover the opened cell tops with a folded paper towel.

Make sure you are present during equalization so you can
monitor the charging cycle.

To start an equalization cycle:

1. Make sure the charger is on and the batteries are fully

charged.

2. Press

SET

until

SEL appears.

3. Press

SET

and

CHARGE

simultaneously until the

CHG

LED starts flashing and

00E goes out (about five

seconds). The

CHG

LED flashes throughout the

equalization cycle.

To end an equalization cycle manually:

Press

SET

until

SEL appears, and then press

SET

and

CHARGE

simultaneously.

The

CHG

LED goes out and the Freedom Inverter/

Charger is forced to float when equalization ends (the

FLOAT

LED comes on).

If you do not stop the equalization process manually, the
cycle ends automatically after eight hours. It also ends if
external AC power is interrupted.

To end equalization early on Freedom inverters that have a
serial number lower than 100,000, turn off both the

CHARGE

and

INVERT

buttons.

CAUTION

Turn off all DC loads before you start equalization. The
voltages required during equalization can damage
sensitive equipment.