Changing the time remaining setting – Xantrex Technology Link 1000 User Manual

Page 34

Advertising
background image

About Link 1000 Settings

26

To change the Charged Current Percentage:

1. Press and hold

SET

until

SEL appears.

2. Press

SEL

twice. The

LED comes on and

002 is

displayed.

3. Press and hold

SET

.

The display moves up in one percent steps until

7

percent is displayed. The display then rolls over and
starts counting up from 1 percent.

4. Release

SET

when the appropriate percentage appears.

Changing the Time Remaining Setting

The Link 1000 has four ways of calculating the amount of
operating time that remains. You can select:

Present consumption level

A four minute average

A sixteen minute average

A thirty-two minute average

The best setting depends on your type of installation.The four
minute average is appropriate for most installations.

To change the Time Remaining setting:

1. Press

SET

until

SEL appears.

2. Press

SEL

four times until the

LED comes on and

001 appears.

3. Press

SET

until the number you want appears. The

display moves up in 1 unit steps with choices of:

4. Release

SET

when the value you want appears.

000

Present consumption

001

4 minute average

002

16 minute average

003

32 minute average

Advertising