Charging functions, Summary of charger status leds – Xantrex Technology Link 1000 User Manual

Page 47

Advertising
background image

Charging Functions

39

Charging Functions

Charge your batteries when two yellow LEDs are lit on the

BATTERY

STATUS

light bar (if you are using the default setting

for F09: Low Battery Discharge Floor). The two yellow
LEDs indicate that 50% of battery capacity has been used.

Charging at this level is called the Mid-Capacity Rule. In
marine and RV systems, which try to minimize charging time
with an engine-driven alternator, or generator-powered
charging, the battery is normally charged to the 85% level.
This means that only 35% of the battery capacity is actually
available for use.

The Mid-Capacity Rule is designed to optimize battery life.

Four charging cycles are available: Bulk, Acceptance, Float,
and Equalization. When you start a charge cycle, the charger
automatically completes a Bulk, Accept, and Float charge.
You can also start an Equalization charge manually.

The

CHARGER

STATUS

LEDs are explained below, and then

procedures are given for charging and equalizing the
batteries.

Summary of CHARGER STATUS LEDs

This LED

Indicates

AC

IN

(green)

AC power is present.

CHG

(red)

on solid

The batteries are in Bulk charge mode.

CHG

(red)

flashing

An Equalization charge is being applied.

ACCEPT

(orange) The batteries are in Acceptance mode.

FLOAT

(green)

The charge is in Float mode.

Advertising