Synchronizing the link 1000 to the battery – Xantrex Technology Link 1000 User Manual

Page 52

Advertising
background image

Charging Functions

44

Synchronizing the Link 1000 to the Battery

When the battery is fully charged, the Link 1000 displays 0
Ah. This indicates that no energy has been removed from the
battery. (The display can also show a positive number; this
changes to 0 as soon as you place a load on the battery. See

page 45

for details about over-charge Ah).

As the battery discharges, the display shows how much
energy has been used. For example, when you run a 10 amp
load for one hour, the display shows

–10 to indicate that 10

Ah have been used.

In other words, the Ah display tells you how much energy has
been removed from the battery as long as the Link 1000 is
synchronized with the battery.

If you install the Link 1000 on a fully charged battery, it
is automatically synchronized to the battery.

If you install the Link on a battery that is partially
charged, you must synchronize the Link by following the
procedure given here.

Once the Link 1000 is synchronized, it stays
synchronized as the battery runs through discharge /
charge cycles. If the Link every gets out of sync with the
battery (this rarely happens), you can synchronize it once
again by following the procedure given here.

To synchronize the Link 1000 to the battery:

1. Discharge the battery by at least 10% of its declared

capacity.

2. Set the Ah reading to 0 by:

a) Holding down

SET

until

SEL appears in the display.

b) Pressing

SET

five times until the

RESET

LED comes

on and

AH appears.

c) Pressing

SET

until

ALL appears. (Be sure to release

SET

as soon as

ALL appears.)

4. Charge the battery until the green

FLOAT

LED comes on.

(For battery charging procedures, see

page 40

.)

Overcharge Ah are displayed as a positive number. When
the battery starts to discharge, the Link resets Ah to zero.

Advertising