Figure 142 syslog: server setup, Table 93 syslog: server setup – ZyXEL Communications GS-4012F/4024 User Manual

Page 234

Advertising
background image

GS-4012F/4024 User’s Guide

Chapter 35 Syslog

233

Figure 142 Syslog: Server Setup

The following table describes the labels in this screen.

Table 93 Syslog: Server Setup

LABEL

DESCRIPTION

Active

Select this check box to have the device send logs to this syslog server. Clear the

check box if you want to create a syslog server entry but not have the device send

logs to it (you can edit the entry later).

Server Address

Enter the IP address of the syslog server.

Log Level

Select the severity level(s) of the logs that you want the device to send to this

syslog server. The lower the number, the more critical the logs are.

Add

Click Add to save your changes to the switch’s run-time memory. The switch loses

these changes if it is turned off or loses power, so use the Save link on the top

navigation panel to save your changes to the non-volatile memory when you are

done configuring.

Cancel

Click Cancel to reset the fields.

Clear

Click Clear to return the fields to the factory defaults.

Index

This is the index number of a syslog server entry. Click this number to edit the

entry.

Active

This field displays Yes if the device is to send logs to the syslog server. No displays

if the device is not to send logs to the syslog server.

IP Address

This field displays the IP address of the syslog server.

Log Level

This field displays the severity level of the logs that the device is to send to this

syslog server.

Delete

Select an entry’s Delete check box and click Delete to remove the entry.

Cancel

Click Cancel to reset the fields.

Advertising