Operating modes 57, 58 z series™ user’s guide – Zebra Technologies Zebra Z4000 User Manual

Page 66

Advertising
background image

Refer to Table 8 if the settings need to be changed to match those of

your host computer. If you do not know the settings of your host com-

puter, refer to the instruction manual provided with the computer.
The serial port supports an Error Detection Protocol which sends and

receives data in packets. This “Zebra” protocol must be compatible

with your host computer and your application software. Received

packets are checked for accuracy. If received correctly, the data in the

packet is processed and an “acknowledge” packet is sent back to the

host. If an error is found in the received packet, either a “negative

acknowledge” packet or no response will be sent to the host. DO NOT

enable Error Detection unless your host is programmed to use it. For

additional information, refer to the ZPL II Programming Guide.

If the Bank One switches are in the proper position to match the com-

munication configuration of the host computer, and the printer is not

receiving data, see Appendix B to make sure you are using the correct

interface cable.

58

Z Series™ User’s Guide

BAUD RATE

SWITCH 1

SWITCH 2

SWITCH 3

9600

ON

ON

ON

19200

OFF

ON

ON

28800

ON

OFF

ON

38400

OFF

OFF

ON

600

ON

ON

OFF

1200

OFF

ON

OFF

2400

ON

OFF

OFF

4800

OFF

OFF

OFF

DATA BITS

SWITCH 4

NOTE: The printer requires one (1)

stop bit minimum on received data

and automatically supplies two (2)

stop bits for transmitted data.

8 Data Bits

ON

7 Data Bits

OFF

HANDSHAKE

SWITCH 5

Xon/Xoff

ON

DTR/DSR

OFF

PARITY

SWITCH 6

SWITCH 7

Parity Disabled

ON

ON

Even

OFF

ON

Odd

ON

OFF

Parity Disabled

OFF

OFF

ERROR DETECTION

SWITCH 8

NOTE: Zebra Protocol is the default

Error Detection Protocol enabled

when “On - Switch 8 OFF” is selected.

Off

ON

On

OFF

Table 8. Bank 1 Switch Settings

ON

OFF

DIP Switch

Positions

66