Rs-232 serial 70, Rs-232 70, Appendix b – Zebra Technologies Zebra Z4000 User Manual

Page 79: Communication interfaces, Serial data communications, Z series™ user’s guide 71

Advertising
background image

Communication Interfaces

Data cables must be fully shielded and fitted with metal or metalized

connector shells to prevent radiation and reception of electrical noise.

To minimize electrical noise pickup in the cable:

n

Keep data cables as short as possible.

n

Do not bundle the data cables tightly with power cords.

n

Do not tie the data cables to power line conduits.

Serial Data Communications

Table 11 illustrates the pin connections on the DB-25 connector at the

rear of the printer.

Z Series™ User’s Guide

71

Appendix B

PIN NO.

DESCRIPTION

1

Chassis Ground

2

TXD (Transmit Data) output from the printer

3

RXD (Receive Data) input to the printer

4

RTS (Request To Send) output from the printer

5

Not Used

6

DSR (Data Set Ready) input to the printer

7

RS-232 Signal Ground

8

Not Used

9

+5V @ 1A source

10

Not Used

11

RS-485 Signal Ground

12

Not Used

13

RS-485 Input B (-)

14

RS-485 Output B (-)

15

Not Used

16

RS-485 Input A (+)

17-18

Not Used

19

RS-485 Output A (+)

20

DTR (Data Terminal Ready) output from the printer

21-25

Not Used

Table 11. Rear Panel Serial Data Port Pinout