CALIBRATION

PARAMETER

SELECTIONS

MEDIA POWER UP

(password

required)

This parameter establishes the action of the media

when the printer is turned ON.

Default: Calibration

Choices: Calibration - recalibrates media and ribbon

sensors by feeding labels

Feed - feeds the label to the first web

Length - determines the length of the label

by feeding labels

No Motion - media does not move

HEAD CLOSE

(password

required)

This parameter establishes the action of the media

after the printhead has been opened and then

closed.

Default: Calibration

Choices: Calibration - recalibrates media and ribbon

sensors by feeding labels

Feed - feeds the label to the first web

Length - determines the length of the label

by feeding labels

No Motion - media does not move

MANUAL CALIBRATE If the auto-calibration feature has been disabled by a

ZPL command from the host or the HEAD CLOSE

parameter is not “Calibrate”, you may use this

feature to calibrate the media and ribbon sensors.

Press “+” to enable the Calibration process.

NOTE: If the printer is configured for continuous

media, no media movement will occur during

the Calibration process.

SENSOR PROFILE

The Media and Ribbon Sensor Profile provides a

graphical representation of the Media and Ribbon

Sensor settings as an aid to the Service Technician if

problems with inter-label gap sensing occur.

Press “+” to enable the Sensor Profile printout.

WEB S.

THESE SETTINGS SHOULD ONLY BE CHANGED

BY AN AUTHORIZED SERVICE TECHNICIAN.

(A password is required)

Refer to the Z Series Maintenance Manual for

additional information about these settings.

MEDIA S.
RIBBON S.
MEDIA LED
RIBBON LED

Continued on the following page.