Aastra 6739i passwords – AASTRA 6739i for OpenCom 1000 User Guide EN User Manual

Page 34

Advertising
background image

Configuring the Aastra 6739i

30

8. Close the Cfg. Svr. menu card with the

softkey.

The Advanced menu card appears.

9. Press the Network softkey.

10.Press the DHCP settings softkey.

11.Select the Use DHCP? -> Disabled setting.

12.In addition, use the IP Address and Subnet Mask softkeys to enter the desired

address configuration manually.

The network configuration entered manually is used after the next restart of the
Aastra 6739i. Then the Aastra 6739i loads files from the TFTP server of the commu-
nications system. Then if necessary the firmware version of the Aastra 6739i is
changed to a version suitable to the communications system. In addition, the
Aastra 6739i loads and activates the configuration specified by the communica-
tions system.

Aastra 6739i Passwords

Certain functions of the Aastra 6739i can only be accessed via password for
security reasons:

Login of the Aastra 6739i: Under Callno./ID enter your call number. Under
PIN enter the password the administrator of the OpenCom 1000
communications system has provided you (please refer to Flexible Workstation
starting on page 18).

Web Configurator of the OpenCom 1000 (OCW): In the password dialogue
of the Web browser enter the user name connected with your call number. The
user name is usually identical with your call number. Enter the password that
the administrator of the OpenCom 1000 communications system gave you.
(please refer to the Web Configurator of the OpenCom 1000 starting on
page 20).

Local settings on the telephone: The factory settings password is “22222”.
After the first log in of the Aastra 6739i onto the OpenCom 1000
communications system this password is overwritten by the communications
system for security reasons.

Advertising