Gpis out - function, Gpis out - type, Gpis out - advance – EVS XT3 Version 11.00 Configuration Manual User Manual
Page 177: Gpis out - pulse duration

GPIs OUT - Function
Description
Specifies the function that activates the output line.
Values
The following functions can be triggered by a GPI OUT:
•
Replace
GPIs OUT - Type
Description
Specifies the type of GPI output signal that will trigger the
specified function.
Values
The following values are possible:
•
close
The level changes to high level at
activation.
•
close
pulse
A rising edge pulse is generated at
activation.
•
open
The level changes to low level at
activation.
•
open
pulse
A falling edge pulse is generated at
activation.
GPIs OUT - Advance
Description
Defines the time (number of seconds and/or frames), at which
the output will be generated ahead of the timecode linked to
the output line.
Values
•
00s00fr to 02s00fr
•
Disable
Default value
Disable
GPIs OUT - Pulse duration
Description
Defines the pulse duration (number of seconds and/or frames)
for pulse type output lines.
Values
•
00s00fr to 02s00fr (2fr steps)
•
Disable
Default value
Disable
171
3. Multicam Configuration
EVS Broadcast Equipment S.A. - April 2012
Issue 11.00.C