The following screenshot presents the page 1 of the Channels tab, where the port settings
are available in the server-based application, and highlights the port settings field group:

RS422 #1 - #6

Description

Specifies what type of device/controller is connected to each
RS422 port of the EVS server.

Values

The following values can be available if the required license
codes are active:

•

'EVS Remote' for LSM Remote Panel (code between 103
and 109).

•

'EVS Remote' for XSense Remote Panel (code between
103 and 109 or code 96)

•

'EVS IPDP' (code 120 or 121)

•

'Sony BVW75' (code 118)

•

'XtenDD35' (code 118)

•

'Odetics' and 'Odetics FK' (code 119)

•

'VDCP' and 'VDCP FK' (code 119)

•

'EVS AVSP' (code 120 or 121)

•

'Edit Rec' (code 122)

•

'Linx' (code 123)

•

'Touch screen'

Default

On port #1 (only): IPDP

Rules

The following rules are applicable for assigning the following
controlling devices to RS422 ports:

•

In all base configurations that rely on an EVS Remote
Controller, the 'EVS Remote' shall always to be assigned
to the first allocated RS422 port.

•

A touch screen can only be assigned to port 6.