Series – Ohaus Valor 7000 Series COMPACT FOOD SCALES Manual User Manual

Page 10

Advertising
background image

EN-8

Valor™ 7000

Series

3.5 Check Mode

Use this mode to compare the Weight or Percent of items to a target range. The scale supports

positive, negative and zero check weighing.

Refer to section 4.5 to set the desired Check sub-mode.


3.5.1 Check Weighing

Set Checkweigh to Weight in the Mode menu. Use this mode to compare the weight of items to

a target weight range.
1. Press and hold Mode until [CHeCk] (Check) is displayed. [CL.lImM] (clear check limits)

will then display.

2. Press No to use the stored check limits and proceed to step 5.
3. Press Yes to establish new check limits. The scale will then display [Set. Lo]. Press Yes

to view the “Low” limit value. Press Yes to accept or No to edit the “Low” limit value. The

stored value then displays with the first digit highlighted [

0

00.000 kg]. Repeatedly press

No until the desired number appears. Press Yes to accept and highlight the next digit.

Repeat until all the digits are correct. Press Yes to accept the “low” limit value, [Set. Hi]

will be displayed.

4. Repeat the same procedure to accept or edit the “high” value.
5. If required, place an empty container on the pan and press Tare.
6. Place sample material on the pan or in the container. If the sample weight is under the

target weight range, the yellow LED will light. If the sample is within the target weight

range, the green LED will light. If the sample is over the target weight range, the red LED

will light.

Note:

Press Function to view the low and high check limits.


3.5.2 Check Percent

Set Checkweigh to Percent in the Mode menu. Use this mode to compare the percentage of

items to a target percent range.

1. Press and hold Mode until [CHeCk] (Check) is displayed. [CLr.ref] (clear reference) will

then display.

If no reference weight exists, the scale will display [Put.ref], proceed to step 4.
2. Press No to use the stored reference weight and proceed to step 5.
3. Press Yes to establish a new reference. Scale will now display [Put.ref].
4. Add the desired reference material to the pan or container. Press Yes to store the

reference weight.

5. The scale will display [CL.lImM] (clear Check limits).
6. Press No to use the stored check limits and proceed to step 9.
7. Press Yes to establish new check limits. The scale will then display [Set. Lo]. Press Yes

to view the “Low” limit value. Press Yes to accept or No to edit the “Low” limit value. The

stored value then displays with the first digit highlighted [

0

00.000 %]. Repeatedly press

No until the desired number appears. Press Yes to accept and highlight the next digit.

Repeat until all the digits are correct. Press Yes to accept the “low” limit value, [Set. Hi]

will be displayed.

8. Repeat the same procedure to accept or edit the “high” value.

Advertising