4.7 Print1 Menu

Enter this menu to set printing parameters. Default settings are bold.
Note:

The Print2 menu is only displayed if a second interface is installed.

Reset

[reset]

Reset the Print menu to factory defaults.

NO

= no reset

YES

= reset

Stable Only

[Stable]

Set the printing criteria.

OFF

= values are printed immediately

ON

= values are only printed when the stability criteria are met

Auto Print

[A.Print]

Set the automatic printing functionality.

OFF

= disabled

ON.STAB

= printing occurs each time the stability criteria are met

1

INTER

= printing occurs at the defined interval

2

CONT

= printing occurs continuously

ACCEPT

= printing occurs each time the display is within the Checkweigh accept

range and stability criteria are met.

1

When ON.STAB is selected, set the condition for printing, where:

LOAD

= printing occurs when the load is stable and greater than zero

LOAD.ZR

= printing occurs when any load is stable and equal to or greater

than zero.

2

When INTER is selected, set the Print Interval.

1 to 3600 (seconds)

Reset:

no

, yes

Stable Only:

off

, on

Auto Print:

off

, on stable, interval, continuous, accept

Content:

Result (-> off, on)

Gross (-> off, on)

Net (-> off, on)

Tare (-> off, on)

Header (-> off, on)

Footer (-> off, on)

Mode (-> off, on)

Unit (-> off, on)

Info (-> off, on)

Accu (-> off, result, all)

Layout:

Format (->S,M)

Feed (->Line, 4 Lines, form)

Data Transfer: off, on

End Print:

Exit menu