Valor™ 7000, Series en-21 – Ohaus Valor 7000 Series COMPACT FOOD SCALES Manual User Manual

Page 23

Advertising
background image

Valor™ 7000

Series EN-21

4.8 COM1 Menu

Enter this menu to define communication parameters. Default settings are bold.


Note:

The COM2 menu is only displayed if a second interface is installed.

Reset

[reset]

Reset the COM menu to factory defaults.

NO = no reset

YES = reset

Baud Rate

[BAUD]

Set the baud rate.

300

= 300 bps

600

= 600 bps

1200

= 1200 bps

2400

= 2400 bps

4800

= 4800 bps

9600

= 9600 bps

19200

= 19200 bps

Parity

[paritY]

Set the data bits and parity.

7 EVEN = 7 data bits, even parity

7 ODD

= 7 data bits, odd parity

7 NONE = 7 data bits, no parity

8 NONE = 8 data bits, no parity

Stop bit

[stOP]

Set the number of stop bits.

1

= 1 stop bits

2

= 2 stop bits

Handshake

[H.shake]

Set the flow control method. Hardware handshaking is only available for COM1 menu.

NONE

= no handshaking

ON-OFF = XON/XOFF software handshaking







Reset:

no

, yes

Baud Rate:

300…9600…19200

Parity:

7 even, 7 odd, 7 none, 8 none

Stop bit:

1

, 2

Handshake:

none

, On-Off

Alternate command: Print (A…P…Z), Tare (A…T…Z), Zero (A…Z)

End COM:

Exit menu

Advertising