3.6 Accumulation and Statistics

The Accumulation feature enables manual or automatic totalizing of displayed values. Statistical

data (total accumulated, min and max weight or %, and total number of weighments) is stored in

memory for review and printing. Accumulation works together with each application mode

except Dynamic.


3.6.1 Accumulating Displayed Values

With ACCUMULATE set to MANUAL, place the item on the scale and press the M+ key to add

the weight to accumulation data. The ∑ pointer will keep flashing until the weight is removed.

With ACCUMULATE set to AUTO, place the item on the scale. The displayed value is

accumulated automatically. The ∑ pointer will keep flashing until the weight is removed.


3.6.2 Viewing and Clearing Statistical Data

When the pan is cleared, press the M+ key to display the statistical information. To clear the

accumulation data press the Tare key while the statistical information is displayed. The display

shows [Clr.aCC]. Press the Yes key to clear the stored data and return to current mode.
Notes:

The item must be removed from the pan before the next item can be accumulated.

Only stable weights are stored to accumulation data.

Changing the mode will clear the accumulation data.

When Legal for Trade is ON, the display must return to 0 gross. Otherwise, the ∑

pointer will continue flashing. Gross loads and net loads cannot be added to the

same total. If the first load is a gross weight, future loads must also be gross

weights. If the first load is a net weight, future loads must also be net weights.

Example:

In weighing mode; sub menu ACCUmM setting, select mMaNU:

If required, place an empty container on the pan and press Tare.

Step i: Put the weight (0.04 kg) on the pan and press M+ key. The Σ

pointer indicator will keep flashing until the weight is removed.

Step ii: Remove the weight from the pan. Put another

weight (0.03 kg) and press M+ key:

Step iii: Remove the weight from the pan:

Step iv: Press M+ key to display the statistical information:

Step v: If required, follow section 3.6.2 to clear the accumulation data.

mMaNU

*

0.040 kg

*

0.030 kg

*

0.000 kg

N 2

tOtal

*

0.070 kg

mMIN

0.030 kg

mMAX

0.040 kg

Advertising