VEGACOM 557 VEGA ASCII

27

Start character: S1 = 1 character "=“
Start character: S2 = "#“
Separating character: T1,T2,T3 = per 1 character "p“
Total length of the telegram: 32 characters

Telegram from processing system to VEGACOM 557

Identifier: 1 character, optional "P“ or "p“
End identification: 1 character Chr (13) = CR = Carriage Return
Total length of the telegram: 5 characters

Error information
0: No error
1: Error on DCS 1
2: Error on DCS 2
3: Error on DCS 1+2
4: Error on DCS 3
5: Error on DCS 1 + 3
6: Error on DCS 2 + 3
7: Error on DCS 1,2 + 3

Answer of VEGACOM 557

(structure also value for DCS value 2 and 3)

Data image in VEGACOM 557

Address Address End

Identifier

VEGACOM

VEGAMET identification

No. of bytes

1

1

2

1

Range (ASCII)

p (P)

0..9

01..15

CR

Example

p

1

02

CR

Addr Addr

DCS

DCS

DCS

Error

End

S1 COM MET S2 Value1 T1 Value2 T2 Value3 T3

info

identification

No.of bytes 1

1

1

1

7

1

7

1

7

1

1

2

Range (ASCII) = 0..9 01..15 # ASCII p ASCII p ASCII p

0..7

CRLF

Example =

1

02

# 00172 p 00384 p 00457 p

0

CRLF

"-“ for negative values
" " for positive values

7

1 2 3 4 5 6

6 digit figure
without decimal point

High resolution = switch 2.2 = ON

The same enquiry can also be carried out with high resolution. The enquiry to VEGACOM 557
remains the same, in the answer more characters are used for the presentation of the meas-
ured value.