VEGA VEGACOM 557 VEGA ASCII protocol User Manual

Page 45

Advertising
background image

VEGACOM 557 VEGA ASCII

45

4.13

Parameter adjustment of VEGALOG or VEGAMET via VEGA ASCII

VEGACOM 557 also provides the option of enquiring and modifying different parameters of
the VEGALOG or VEGAMET signal conditioning instruments (relating to measurement loop).
The following list gives an overview of the affected parameters:

Parameter name

possible access mode

Density

reading

writing

Relay switching point (top)

reading

writing

Relay switching point (bottom)

reading

writing

Integration time

reading

writing

Scaling (0 %)

reading

writing

Scaling (100 %)

reading

writing

Current offset

reading

writing

Activate offset adjustment

writing

Independent of the connected VEGA signal conditioning instrument (VEGAMET or VEGA-
LOG), the enquiry or modification of parameters is made via the VEGA ASCII always accord-
ing to the same procedure. Each enquiry starts with the identifier "?“ followed by "R“ for Read
or "W“ for Write as well as the identifier for the parameter. The telegrams are completed by the
addresses of VEGACOM, VEGAMET and the component number as well as the value to be
written.

If it was not possible to transfer the order to a connected instrument, as message with the
value, or with information about the action just carried out, is returned.

For further information, please contact one of our employees.

Data image in VEGACOM 557