VEGACOM 557 VEGA ASCII

4.2 Enquiry for VEGAMET with up to seven values per instrument

Low resolution = switch 2.2 = OFF

VEGAMET instruments can be provided with up to 7 DCS outputs. With this telegram, it is
possible to read all DCS values from one instrument.

Telegram from processing system to VEGACOM 557

Identifier: 1 character, optional "M“ or "m“
End identification: 1 character Chr (13) = CR = Carriage Return
Total length of the telegram: 5 characters

"-“ for negative values
" " for positive values

(Structure is valid for all DCS values)

Answer of VEGACOM 557

Start character: S1 = 1 character "=“
Start character: S2 = 1 character "#“
Separating character: Tx = per 1 character "p“
Total length of the telegram: 66 characters

Error information
1. position

0: No error on DCS 1,2,3
1: Error on DCS 1
2: Error on DCS 2
3: Error on DCS 1+2
4: Error on DCS 3
5: Error on DCS 1 + 3
6: Error on DCS 2 + 3
7: Error on DCS 1,2 + 3

2. position

0: No error on DCS 4,5,6
1: Error on DCS 4
2: Error on DCS 5
3: Error on DCS 4+5
4: Error on DCS 6
5: Error on DCS 4 + 6
6: Error on DCS 5 + 6
7: Error on DCS 4,5 + 6

3. position

0: No error on DCS 7
1: Error on DCS 7

7

1 2 3 4 5 6

3 positions in front of decimal point
1 decimal point
1 position after the decimal point

1 during simulation
" " during operation

Data image in VEGACOM 557

Address

Address

End

Identifier

VEGACOM

VEGAMET identification

No. of bytes

1

1

2

1

Range (ASCII)

m (M)

0..9

01..15

CR

Example

m

1

2

CR

Addr Addr

DCS

Error

End

S1 COM MET S2

value2 T2

T3

info

identification

No. of bytes 1

1

1

1

7 X

7

1

1

1

2

Range (ASCII) = 0..9 01..15 #

ASCII p

p

0..7

CRLF

Example =

1

02

#

38.4

p

p

0

CRLF