Table 1: economind troubleshooting – Banks Power Chevy_GMC Trucks: Duramax LMM (Diesel ’07 - 10 6.6L) Power Systems- PowerPack & Stinger w_EconoMind ('07-09) LMM (PDA) Compatible w_Optional PowerPDA User Manual

Page 57

Advertising
background image

96507 v.4.0

57

Code

PDA Error Message

Corrective Action

1,1

Fuel Rail Pressure (FRP)

Input Voltage Out of

Range.

Turn ignition OFF for 60 seconds and check the black and gray

connectors.

1,2

Manifold Absolute

Pressure (MAP) Input

Voltage Out of Range.

Turn ignition OFF for 60 seconds and check the gray and black

connectors.

1,3

EconoMind Switch

Input Value Out of

Range.

Turn ignition OFF for 60 seconds and make sure either Banks

PowerPDA or EconoMind Switch is connected to the EconoMind

Tuner. If the EconoMind Switch is connected (no Banks

PowerPDA), check the 2-terminal connection on Tuner’s In-Cab

cable. If the PowerPDA is connected (no Banks EconoMind Switch),

check the 4-terminal connection on the Tuner’s In-Cab cable.

1,4

Mass Air Flow (MAF)

Input Voltage Out of

Range.

Turn ignition OFF for 60 seconds and check the 5-Terminal MAF

connector.

2,1

Fuel Rail Pressure (FRP)

Output Voltage Out of

Range.

The FRP sensor may be bad. Turn ignition OFF for 60 seconds and

check the gray and black connectors.

2,2

Manifold Absolute

Pressure (MAP) Output

Voltage Out of Range.

The MAP sensor may be bad. Turn ignition OFF for 60 seconds and

check the black and gray connectors.

2,3

Exhaust Gas

Temperature (EGT)

Sensor circuit Fault.

Turn ignition OFF for 60 seconds and check the thermocouple

connectors.

2,4

Mass Air Flow (MAF)

Output Voltage Out of

Range.

The MAF sensor may be bad. Turn ignition OFF and check the

5-Terminal MAF connector.

3,1

Engine Position Sensor

Fault.

Turn ignition OFF for 60 seconds and check the gray and black

connectors.

3,2

Internal Module

Malfunction or

Intermittent Power.

Turn ignition OFF for 60 seconds and check the black and gray

connectors. Check the Tuner’s fuse.

3,3

EGR Valve Position

Input Voltage Out of

Range.

Turn ignition OFF and check the black and gray connectors.

3,4

OBDII cAN

communication error

Turn ignition OFF for 60 seconds and check the gray and black

connectors.

4,1

Injection Control Signal

Fault.

Turn ignition OFF for 60 seconds and check the gray and black

connectors.

4,2

Transmission Slippage

Detected.

Transmission is slipping excessively. Code will automatically clear

once transmission stops slipping (repaired). If code is thrown,

torque convertor needs to lock and unlock 5x before code is

cleared from transmission.

4,3 or 4,4 Internal Module

Malfunction.

Turn ignition OFF. Turn ignition back ON after 60 seconds and

re-check for presence of code. If error is still present, turn ignition

OFF and check all connectors. Check the Tuner’s fuse.

Table 1: EconoMind Troubleshooting

If any code is displayed or is persistent, pull the connectors apart and check the terminals. A terminal

may not have been seated correctly during manufacturing and it may have moved when connected. If it

appears that a terminal has moved, gently pull on it with small needle nose pliers to lock it in place.

Advertising