Plc watchdog – Grain Systems PNEG-1755 User Manual

Page 14

Advertising
background image

4. PLC WatchDog Operation

14

PNEG-1755 PLC WatchDog

PLC WatchDog

Figure 4D

Variables that may be edited here are:

(See Figure 4D.)

IP Address - Address that the SMTP server is using to forward messages.

SMTP Domain - Domain name of SMTP server.

Email User - Email address to receive alarm messages.

SMS Text User - Text messaging account information*.

Grain Temp - °F setpoint for grain temperature.

Unload Rate - Speed setpoint for unload conveyor.

Dry Setpoint - Percent moisture setpoint for dry grain.

Plenum Temp - °F setpoint for plenum temperature.

Test Other Email - Turn “ON” for testing new email and text account settings.

For additional information on updating the PLC with new variable information, refer to Remote View -
System Variables

on Page 25

and Email Settings section

on Page 26

of this manual.

*For a list of common SMS carriers and their account formatting, see

Appendix B on Page 32

.