Chapter 10 ladder, Optional sidewall ladder, Ladder – Grain Systems Tanks PNEG-256 User Manual
Page 52
52
PNEG-256 6', 7' & 9' Bulk Feed Tanks
10. LADDER
Optional Sidewall Ladder
Instructions
To start sidewall ladder, places two outside standoffs spaces 18.3/4" (476 mm) apart. At the roof
eave, the ladder should be located on the standoffs. (Refer to drawing). Continue with standoff
located on every horizontal seam. Ladder support ring should be located between two legs as
shown. This will support the ladder at the bottom of bulk feed tank. When positioning the ladder
on the tank, be sure to attach ladder so the raised non-slip tread surface is to the top of the
ladder rungs.
Figure 10A Sidewall Ladder Detail
Ladder Standoff Ring
Qty
6'
BLK-10147
1
7'
BLK-10148
2
9'
BLK-10149
3
Roof Eave
Safety Rail
Sidewall
Ladder Standoff
Roof Panel
Ladder Section
6.25" (159 mm)