Chapter 10 ladder, Optional sidewall ladder, Ladder – Grain Systems Tanks PNEG-256 User Manual

Page 52

Advertising
background image

52

PNEG-256 6', 7' & 9' Bulk Feed Tanks

10. LADDER

Optional Sidewall Ladder

Instructions

To start sidewall ladder, places two outside standoffs spaces 18.3/4" (476 mm) apart. At the roof
eave, the ladder should be located on the standoffs. (Refer to drawing). Continue with standoff
located on every horizontal seam. Ladder support ring should be located between two legs as
shown. This will support the ladder at the bottom of bulk feed tank. When positioning the ladder
on the tank, be sure to attach ladder so the raised non-slip tread surface is to the top of the
ladder rungs.

Figure 10A Sidewall Ladder Detail

Ladder Standoff Ring

Qty

6'

BLK-10147

1

7'

BLK-10148

2

9'

BLK-10149

3

Roof Eave
Safety Rail

Sidewall

Ladder Standoff

Roof Panel

Ladder Section

6.25" (159 mm)