14 PNEG-1555 8" Commercial Vertical Drive Unit - Dual Drive
4. Installation
H. Remove the horizontal head plate from the vertical auger by removing the eight (8) 5/16'' x 1''
hex bolts, flat washers, lock washers and hex nuts.
Figure 4D
I. Unbolt and remove the 1-1/4'' four (4) hole flange bearing. Where possible, this bearing will be
reused with the new horizontal drive parts.
Figure 4E