Troubleshooting, Chapter 10 troubleshooting – Grain Systems Unload Augers PNEG-1555 User Manual

Page 34

Advertising
background image

34 PNEG-1555 8" Commercial Vertical Drive Unit - Dual Drive

10. Troubleshooting

Problem

Possible Cause

Solution

Auger vibration

1. Drive belt may be overtightened, putting

head stub and flight in a bind. Damage
can occur to the auger flighting, thus
caused noise. Damage usually caused
from foreign material having been run
through the auger.

1. It may be necessary to remove the flighting

for inspection.

2. Adjust the drive belt to the proper tension

Low capacity

1. The auger may not be getting

enough grain.

1. Check that the intake has not bridged over,

restricting flow. The exposed flighting at the
auger intake should be covered with grain
to achieve maximum capacity.

2. The auger is moving too slowly.

2. Check the auger speed. Speeds slower

than the recommended speed will result in
low capacity.

Auger plugs

1. The auger may be getting too much

grain, causing “jamming” inside
the housing.

1. Decrease the amount of grain the auger

is gathering.

2. The motor may be too small or

wired improperly.

2. If the motor is a newer light weight

aluminum type, the next larger size should
be considered.

3. The grain may be wet.

3. If wet grain or other hard-to-move material

is being augured, use a larger size motor
than recommended for normal use.

4. The auger may be jammed with

foreign material.

4. Be sure there is no foreign material in the

auger such as sacks, tarp corners, etc.

5. The discharge end may be plugged.

5. Make sure the discharge end of the auger

is not plugged. A plug of the discharge end
will cause an auger plug.

Advertising