PNEG-1820 CE Compliant Top Dry Series 2000 Autoflow

7. Control System

Electronic Monitoring Control System

Figure 7A

Electronic Monitoring Control System

This controls all timing functions and safety circuits. It provides printed messages and warnings.

Turn control power to “ON” to start the control. The control will enter the main drying screen.

Setting the Dry, Cool and Unload Timers

These set the dry, cool and dump cycle times. The timer settings are displayed above the Timer button.
To alter the setting:

1. Press the Dry, Cool or Unload Timer button.

2. Press “modify”.

3. Press “increase” or “decrease” to adjust the settings.

4. Press “enter”.

5. To enter the new value into memory, press “reset”.

During drying the remaining time for each timer is displayed. The control retains these values in the event
of a power failure. Pressing “reset” returns the timers to their initial setting. The cool timer is not used in
an Autoflow system.