Valve proving system high gas pressure switch, Valve proving system, High gas pressure switch – Grain Systems PNEG-1820 User Manual

Page 24: Grain high-limit

Advertising
background image

9. Error Messages and Valve Proving System

24

PNEG-1820 CE Compliant Top Dry Series 2000 Autoflow

Grain High-Limit

The grain temperature in the drying chamber is too high.

Valve Proving System

The main safety shut-off valve is fitted with a proving system which will prevent burner start-up if the valve
is leaky.

Figure 9A

Check the light status on the VPS. Red light indicates leaky valve. VPS is reset by pressing the
Reset button.

High Gas Pressure Switch

In addition to the high pressure relief, the main solenoid valve is fitted with a High Pressure switch. This
will cause the burner to shut down if the pressure exceeds the pre-set level.

High gas pressure switch

Valve proving system

Low-fire adjustment screw

High-low valve

Advertising