13. Start-Up Procedure

34

PNEG-1820 CE Compliant Top Dry Series 2000 Autoflow

Normal Start-Up

When the dryer is started with grain in the drying chamber that has already been partially dried, the dryer
can be started without making any adjustments to time or temperature; however, the moisture of the grain
should be checked after the fourth dump.

Last Fill

1. Stop the dryer when all the wet grain has been loaded into the drying chamber and turn OFF the

Moisture Control switch.

2. Set the time on the dry timer for twice the recommended amount using the charts for the specific bin

size, fan and heater size, drying temperature and grain input moisture content.

3. Push the Reset button.

4. Turn the Dry and Hold switch to the “ON” position.

5. Turn the Load Auger switch to the “OFF” position.

6. Press the Start switch.

7. When the dryer shuts down install the fan inlet cover(s).

8. Let the aeration fan cool in the top and store or manually dump into the storage chamber.