5. Assembly

PNEG-1366 12" and 16" Series II Sweep Quick Disconnect Control Box Kit

27

Switch the Manual Mode switch to idle (not reverse or forward).

Depress the pedal in the safety foot switch.

Press the Start button on the control panel.

NOTE: If any damage is observed or there is abnormal operation of the sweep, shut it down immediately.

There are three (3) ways to accomplish this. 1) Remove the pressure on the safety foot switch.
2) Press the Stop button on the control panel. 3) Press in on the Enable/Disable button so that it
collapses appropriately. Switch the disconnect switch on the panel to OFF (not ON). Lock out the
panel before entering the bin to service the sweep.

Observe the no load amps (NLA) displayed on the meter on the front of the panel.

Auger drive motor no load amps: ____

The tractor motor operation (forward and stop) in automatic is dictated by the amp reading on the auger
drive motor.

The tractor drive motor is meant to shut off (idle) when the Auger Drive Motor reaches 90% of the
nameplate FLA.

90% of full load amps: ____

The tractor motor is meant to reactivate (forward) when the auger drive motor reaches 110% of the no load
amps (amperage observed when the auger flight turns freely in absence of grain).

110% of no load amps: ____

Final Display Setup

NOTE: If no keys are activated for 2 minutes, the display returns to the default state without saving any

configuration changes. At each value, after 5 seconds of inactivity, a description of the current
state will scroll across the display.

Press OK repeatedly until RELU is displayed on the unit.

Press

or

on the display unit until DISP is shown (not PERC).

Press OK.

REL1 should be displayed on the unit.

Press

or

on the display unit until SET is shown (not SKIP, or OFF).

Press OK.

SETP should be displayed on the unit.

Press

or

on the display unit the 90% of FLA value is shown.

Press OK.

ACT1 should be displayed on the unit.

Press

or

on the display unit until INCR is shown (not DECR).

Press OK.