Chapter 7: Power Supply

Table 7-1 Specifications for the electrical load on a portable dryer (cont'd.)

Dryer

model

Voltage

Motor

HP

Fuel Load

Amps

Maximum amps

with auxiliaries

Minimum

amps

Recommended

service in amps

Branch breaker

in amps

1226
2140

3 PH 220V

Load auger

10

26

271

149

350

90

Unload auger

10

26

90

Top Fan

25

64

90

Bottom Fan

10 to 12

33

60

(2) Auxiliary

(2) 15

78

*

3 PH 440V

Load auger

10

13

144

77.5

200

60

Unload auger

10

13

60

Top Fan

25

32

60

Bottom Fan

10 to 12

16.5

60

(2) Auxiliary

(2) 15

39

*

1214S

2141

1 PH 230V

Load auger

5

26

252

148

350

100

Unload auger

5

26

100

(2) Fans

(2) 10 to

12

96

100

(2) Auxiliary

(2) 7.5

62

*

3 PH 220V

Load auger

5

13.2

176

92.4

225

60

Unload auger

5

13.2

60

(2) Fans

(2) 10 to

12

66

60

(2) Auxiliary

(2) 10

52

*

3 PH 440V

Load auger

5

6.6

93

46.2

150

60

Unload auger

5

6.6

60

(2) Fans

(2) 10 to

12

33

60

(2) Auxiliary

(2) 10

26

*

1218S

2181

1 PH 230V

Load auger

5

26

252

148

350

100

Unload auger

5

26

100

(2) Fans

(2) 10 to

12

96

100

(2) Auxiliary

(2) 7.5

62

*

3 PH 220V

Load auger

5

13.2

165

82.4

225

60

Unload auger

5

13.2

60

(2) Fans

(2) 10

56

60

(2) Auxiliary

(2) 10

52

*

3 PH 440V

Load auger

5

6.6

87

41.2

150

60

Unload auger

5

6.6

60

(2) Fans

(2) 10

28

60

(2) Auxiliary

(2) 10

26

*

Pneg-1891 Portable Dryers

49